{"product_id":"micropipette-fits-laboratory-research-equipment-replaces-onilab-7010101017","title":"Micropipette – Fits Laboratory Research Equipment (Replaces ONiLAB 7010101017)","description":"\u003csection\u003e\n\u003c!-- 🔧 Table Styles (include only once per page) --\u003e\n\u003cstyle\u003e\n  \/* Outer container allows horizontal scrolling (with iOS momentum) *\/\n  .ss-table-wrap { overflow-x:auto; -webkit-overflow-scrolling:touch; }\n\n  \/* Base table styles *\/\n  table.ss-table { width:100%; border-collapse:collapse; min-width:640px; }\n  table.ss-table th, table.ss-table td {\n    padding:10px 12px; border:1px solid #e5e7eb; text-align:left; vertical-align:top;\n  }\n\n  \/* Key: prevent wrapping, word breaks, and vertical text in headers *\/\n  table.ss-table th {\n    white-space:nowrap;       \/* Do not wrap *\/\n    word-break:normal;        \/* Don’t break words *\/\n    letter-spacing:normal;    \/* Prevent theme styles from stretching letters *\/\n    font-weight:600;\n    background:#f8fafc;\n  }\n\n  \/* Small screen optimization *\/\n  @media (max-width:480px){\n    table.ss-table th, table.ss-table td { padding:8px 10px; font-size:14px; }\n  }\n\u003c\/style\u003e\n\n\u003csection id=\"product-details\"\u003e\n  \u003ch2\u003eProduct Details\u003c\/h2\u003e\n  \u003cp\u003eThis is a \u003cstrong\u003ePipettor Adjustable Variable Volume Micropipette 1000-5000μL\u003c\/strong\u003e (1-5mL), designed for laboratory use in scientific research, medical sampling, and general liquid handling applications. It is an adjustable single-channel pipette built for accuracy and repeatability.\u003c\/p\u003e\n  \u003cp\u003eThis unit serves as a direct replacement for ONiLAB 7010101017, various Four E's Scientific 1-5mL models, and Xin Tester 1000-5000μL pipettors.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cb\u003eInstallation:\u003c\/b\u003e Manual hand-held operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eAutoclaving:\u003c\/b\u003e The lower part can be disassembled and autoclaved at 121°C for sterilization.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eCompatibility:\u003c\/b\u003e Designed to work with standard 5mL pipette tips.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"part-number-matrix\"\u003e\n  \u003ch2\u003ePart Number Matrix\u003c\/h2\u003e\n  \u003cp\u003eUse this matrix to confirm equivalent references across OEM and aftermarket models.\u003c\/p\u003e\n  \u003cdiv class=\"ss-table-wrap\"\u003e\n    \u003ctable class=\"ss-table\" aria-label=\"Part Number Matrix\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eBrand\u003c\/th\u003e\n          \u003cth\u003eModel\u003c\/th\u003e\n          \u003cth\u003eRated Capacity\u003c\/th\u003e\n          \u003cth\u003eOEM Part No.\u003c\/th\u003e\n          \u003cth\u003eNotes\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eONiLAB\u003c\/td\u003e\n          \u003ctd\u003e1000-5000μL Multi-Volume Adjustable\u003c\/td\u003e\n          \u003ctd\u003e1000-5000μL\u003c\/td\u003e\n          \u003ctd\u003e7010101017\u003c\/td\u003e\n          \u003ctd\u003eLower half autoclavable\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eXin Tester\u003c\/td\u003e\n          \u003ctd\u003eHigh Accurate Lab Pipettor\u003c\/td\u003e\n          \u003ctd\u003e1000-5000μL\u003c\/td\u003e\n          \u003ctd\u003e\u003c\/td\u003e\n          \u003ctd\u003eComes with 20 tips\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eFour E's Scientific\u003c\/td\u003e\n          \u003ctd\u003e1-5mL Pipettor\u003c\/td\u003e\n          \u003ctd\u003e1000-5000μL\u003c\/td\u003e\n          \u003ctd\u003e\u003c\/td\u003e\n          \u003ctd\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"technical-specs\"\u003e\n  \u003ch2\u003eTechnical Specs\u003c\/h2\u003e\n  \u003cdl\u003e\n    \u003cdt\u003eProduct Type\u003c\/dt\u003e\n\u003cdd\u003eSingle-Channel Variable Volume Pipettor\u003c\/dd\u003e\n    \u003cdt\u003eInstallation\u003c\/dt\u003e\n\u003cdd\u003eManual hand-held\u003c\/dd\u003e\n    \u003cdt\u003eConnection\u003c\/dt\u003e\n\u003cdd\u003eStandard 5mL pipette tip compatible\u003c\/dd\u003e\n    \u003cdt\u003eHousing Material\u003c\/dt\u003e\n\u003cdd\u003eBody: PP (Polypropylene); Control button \u0026amp; tip ejector: PA (Polyamide)\u003c\/dd\u003e\n    \u003cdt\u003eFitting Type\u003c\/dt\u003e\n\u003cdd\u003eCone tip for 5mL pipette tips\u003c\/dd\u003e\n    \u003cdt\u003eOperating Temperature\u003c\/dt\u003e\n\u003cdd\u003eAutoclavable at 121°C (250°F)\u003c\/dd\u003e\n    \u003cdt\u003eIncrement\u003c\/dt\u003e\n\u003cdd\u003e50μL\u003c\/dd\u003e\n    \u003cdt\u003eOther Technical Attributes\u003c\/dt\u003e\n\u003cdd\u003eLower part can be disassembled and autoclaved\u003c\/dd\u003e\n  \u003c\/dl\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"whats-in-the-box\"\u003e\n  \u003ch2\u003eWhat’s in the Box\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e1 x Micropipette (main body)\u003c\/li\u003e\n    \u003cli\u003e1 x Calibration Oil\u003c\/li\u003e\n    \u003cli\u003e1 x Simple Bracket\u003c\/li\u003e\n    \u003cli\u003e1 x Wrench\u003c\/li\u003e\n    \u003cli\u003e1 x User Manual\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color:#d0021b;\"\u003e20 x Pipette Tips\u003c\/span\u003e (with Xin Tester models)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"installation-notes\"\u003e\n  \u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n  \u003col\u003e\n    \u003cli\u003eEnsure the pipette and tips are clean before use to prevent contamination.\u003c\/li\u003e\n    \u003cli\u003eFirmly press a compatible pipette tip onto the cone to create an airtight seal.\u003c\/li\u003e\n    \u003cli\u003eSet the desired volume by carefully turning the thumb-operated control button.\u003c\/li\u003e\n    \u003cli\u003eTo aspirate, depress the plunger to the first stop, immerse the tip in the liquid, and smoothly release the plunger.\u003c\/li\u003e\n    \u003cli\u003eTo dispense, place the tip against the inner wall of the receiving vessel and slowly depress the plunger to the second (blowout) stop.\u003c\/li\u003e\n    \u003cli\u003eUse the tip ejector button to discard the used tip. Always use a new tip for different samples.\u003c\/li\u003e\n    \u003cli\u003ePeriodically check calibration according to the user manual, especially after autoclaving, using the supplied wrench.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"faq\"\u003e\n  \u003ch2\u003eTroubleshooting \u0026amp; FAQ\u003c\/h2\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow do I select the correct volume?\u003c\/summary\u003e\n    \u003cp\u003eTurn the control button until the digital display shows your target volume. The selectable range is 1000-5000μL with an increment of 50μL.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs the entire pipette autoclavable?\u003c\/summary\u003e\n    \u003cp\u003eNo, only the lower part (piston and tip cone assembly) can be disassembled and autoclaved at 121°C. Autoclaving the entire unit will damage the internal mechanism.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat should I do if the pipette is not aspirating correctly?\u003c\/summary\u003e\n    \u003cp\u003eFirst, check that the pipette tip is attached securely to create an airtight seal. Second, ensure the internal piston is clean and properly lubricated. If issues persist, recalibration may be necessary.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow often should I calibrate the pipette?\u003c\/summary\u003e\n    \u003cp\u003eFor frequent, high-precision work, calibration should be checked every 3-6 months. For general use, annual calibration is sufficient. Always recalibrate after performing maintenance or autoclaving the lower part.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eOEM vs. Aftermarket?\u003c\/summary\u003e\n    \u003cp\u003eThis listing is an afternoon replacement (not OEM). Built to OEM-level specifications with comparable materials. Manufactured in an ISO 9002 facility, batch-inspected for consistency.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eShipping speed \u0026amp; cost?\u003c\/summary\u003e\n    \u003cp\u003eWe ship worldwide quickly—typical transit 5–15 days. Standard shipping is free; expedited options appear at checkout where available.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWarranty \u0026amp; returns?\u003c\/summary\u003e\n    \u003cp\u003eCovered by a 1-year warranty against manufacturing defects under normal use. If issues arise, contact support with your order details. Returns are accepted within our standard window (unused \u0026amp; in original condition). See our policy page or reach out for instructions.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"safety-info\"\u003e\n  \u003ch2\u003eSafety \u0026amp; Important Info\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eVerify images\/specifications vs your original part. If anything differs—even if your model appears compatible—do not purchase.\u003c\/li\u003e\n    \u003cli\u003eThis is an aftermarket replacement, not an OEM component.\u003c\/li\u003e\n    \u003cli\u003eProfessional installation is recommended for safety and performance.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"about-us\"\u003e\n  \u003ch2\u003eAbout Sea Sierra\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cb\u003ePro-Grade Standards\u003c\/b\u003e — We supply marine parts engineered to OEM-level tolerances and tested for real-world conditions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eFast Global Fulfillment\u003c\/b\u003e — Free standard delivery to most regions in 5–15 days.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eManufacturer-Direct Value\u003c\/b\u003e — Fair pricing without compromising on materials or QC.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/section\u003e","brand":"SeaSierra","offers":[{"title":"Default Title","offer_id":50717896671547,"sku":"24PE108","price":39.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/8673\/8747\/files\/24PE108.png?v=1762937716","url":"https:\/\/seasierra.com\/products\/micropipette-fits-laboratory-research-equipment-replaces-onilab-7010101017","provider":"SeaSierra","version":"1.0","type":"link"}