Welcome Aboard!

10% savings across all ranges sitewide for new customers · Terms apply

FLASHSALE26

Adjustable-Volume Micropipette, 0.5–10 μL, Single-Channel

Regular price $29.99

Worry-free returns

Shop with confidence. If you’re not completely satisfied, eligible items may be returned within the return window, provided they are unused and in original packaging.


If the return is due to our error or a defective item, we’ll make it right.


Please contact us before returning any item.

Delivery and Shipping

Orders are typically processed within 1–2 business days.


U.S. orders usually arrive within 6–15 days, depending on stock location and destination.


International delivery times may vary due to customs processing.


Tracking information will be provided once your order ships.

If you have any questions, feel free to email us at info@seasierra.com, and we’ll get back to you within 20–36 hours.

Product Details

This adjustable-volume micropipette is a single-channel, manual laboratory instrument with a 0.5–10 μL operating range. It is designed for controlled liquid handling and features a spring-loaded tip cone for secure attachment of compatible pipette tips and a clear four-digit display for volume setting.

The pipette is suitable for general laboratory applications that require small-volume air-displacement pipetting. Tip compatibility should be confirmed before use, especially when replacing a specific manufacturer’s pipette.

  • Manual handheld operation for flexible laboratory use.
  • Adjustable 0.5–10 μL volume range with 0.1 μL increments.
  • Spring-loaded tip cone helps provide a secure seal with compatible tips.
  • Disassemblable tip core can be autoclaved at 121°C.
  • Four-digit volume display for clear setting and reading.

Reference Compatibility

The supplied listing identifies this volume range as a replacement reference for several similarly specified laboratory micropipettes. These references are provided for comparison only and do not establish manufacturer ownership, OEM status, or universal interchangeability. Confirm the tip interface, volume range, and physical dimensions before ordering.

Reference Brand Product Type Volume Range Compatibility Note
LAB FISH Micropipette 0.5–10 μL Reference model identified in the supplied listing; verify fit before purchase.
ONiLAB Laboratory micropipette 0.5–10 μL Reference model identified in the supplied listing; verify fit before purchase.
Microlit Single-channel laboratory micropipette 0.5–10 μL Reference model identified in the supplied listing; verify fit before purchase.
Four E's Scientific Single-channel pipette 0.5–10 μL Reference model identified in the supplied listing; verify fit before purchase.

Technical Specifications

Product Type
Single-channel adjustable-volume micropipette
Operation
Manual handheld operation
Volume Range
0.5–10 μL
Increment
0.1 μL
Accuracy
±8% at 0.5 μL; ±1% at 10 μL
Precision
±5% at 0.5 μL; ±0.4% at 10 μL
Tip Connection
Spring-loaded tip cone for compatible pipette tips
Housing Material
Polypropylene body; polyamide control button and tip-ejector cap
Housing Color
Medium gray and white
Autoclavability
Tip core can be disassembled and autoclaved at 121°C
Operating Principle
Air displacement
Calibration
Recalibration is possible using the adjustment mechanism and applicable instructions
Display
Four-digit volume display
Additional Adjustment
Temporary adjustment may be used for challenging liquids when appropriate

What's in the Box

The package is supplied as a single adjustable-volume micropipette. Accessory contents should be checked against the shipment documentation; the supplied listing identifies the following items:

  • 1 × Adjustable-volume micropipette
  • Pipette tips or a box of compatible tips, where included; quantity may vary
  • 1 × Operating manual
  • 1 × Adjustment tool
  • 5 × Adjustment seals for temporary adjustment
  • 1 × Tube of pipette grease
  • 1 × Locking ring

Operating Instructions

  1. Set the desired volume by turning the control button until the four-digit display shows the required value.
  2. Press a compatible pipette tip firmly onto the spring-loaded tip cone to create an airtight seal.
  3. Depress the plunger smoothly to the first stop.
  4. Place the tip just below the surface of the source liquid.
  5. Allow the plunger to return slowly and smoothly to aspirate the liquid.
  6. To dispense, place the tip against the inside wall of the receiving vessel and press the plunger to the first stop, then to the second stop to expel remaining liquid.
  7. Press the tip-ejector button to discard the used tip.
  8. For calibration, disassembly, cleaning, and maintenance procedures, follow the included operating instructions.

Troubleshooting & FAQ

How can I improve measurement accuracy?

Use compatible tips that fit securely, pre-wet the tip when appropriate, and operate the plunger smoothly and consistently. Keep the pipette within its specified 0.5–10 μL range and recalibrate it when required by your laboratory procedure. The listed accuracy is ±8% at 0.5 μL and ±1% at 10 μL.

Is the entire pipette autoclavable?

No. The listed autoclavable component is the disassembled tip core, which can be autoclaved at 121°C. Do not place the complete pipette in an autoclave unless the manufacturer’s instructions specifically permit it.

What should I do if the pipette leaks or dispenses inaccurately?

Check that the tip is compatible and fully seated, inspect the tip cone and seal for contamination or damage, and confirm that the selected volume is within the operating range. Cleaning or regreasing may be required according to the operating manual. Recalibrate the pipette if necessary.

Can it be used with viscous or volatile liquids?

Yes, but liquid properties can affect pipetting performance. Use an appropriate technique, such as reverse pipetting where suitable, and follow your laboratory’s validation and calibration procedures for non-aqueous, viscous, or volatile liquids.

Is this an OEM product?

This listing describes an aftermarket laboratory micropipette. The reference brands in the compatibility table are comparison references only; they do not indicate that this product is manufactured by those brands.

How should I confirm compatibility?

Compare the 0.5–10 μL range, tip interface, physical dimensions, and operating requirements with your existing pipette. A matching volume range alone does not guarantee interchangeability.

Safety & Important Information

  • Use the pipette only with compatible tips and within the specified 0.5–10 μL range.
  • Wear appropriate laboratory personal protective equipment and follow applicable liquid-handling procedures.
  • Do not autoclave the complete pipette unless specifically authorized by the operating instructions.
  • Inspect the pipette, tip cone, seals, and tips before use. Do not use damaged equipment.
  • This is an aftermarket replacement and is not represented as an OEM component from the reference brands listed above.

About Sea Sierra

  • We provide replacement products for laboratory and technical applications.
  • Product information is presented to help customers compare specifications and confirm compatibility before purchase.
  • For best results, verify the product dimensions, tip interface, and required operating range against your application.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Cartes Bancaires
  • Diners Club
  • Discover
  • Google Pay
  • JCB
  • Maestro
  • Mastercard
  • PayPal
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.